The transmitter uses microprocessor technology to convert the signal to a 4 to 20ma analog output. Technical documentation f 200 k compact flame detector. Compliance with ceien 501941 certify the absolute reliability and efficiency of the device. The model sae can be calibrated for vppb level detection of two most commonly used challenge halides r11 and r12. This fd series flame detector is the only one on the market that uses patented automatic visual integrity avi testing technology, which continuously checks optical surfaces for contamination while at the same time verifying functionality of the sensors. The omniguard model 860 uvir flame detector is designed to detect unwanted fires, and output appropriate alarm information.
New microprocessor technology makes the detectors independent of flame intensity enabling it to operate through smoke, a layer of oil. The nucon model sae is the only continuous halide detector available that meets ansiasme standards n510 and ag1. Proper analog signal loop resistance must be installed as documented in the instruction manual to enable proper 420 ma signal function. The evolution continues with the new x5200 uvir flame detector. This report presents flame response, horizontal and vertical field of view data for various fuel types, fire sizes and detector sensitivities. Uvir flame detector user and maintenance manual zeta alarm. Dettronics instructions uvir flame detector with pulse. Uvir flame detector it appears you dont have a pdf plugin for this browser. Gc2400rxn gc2600rxex gc2200rxgc9600rx gc9800rxgc3200rx, gc6000rxgc3300rx. This can be overcome by going to detectors with higher densities solids, liquids.
Gas alarm electronics gas detector transmitter type. New enhanced detector capabilities teledyne judson. Reduced maintenance costs with easy access for testing detectors, in hard to reach places. The pulseoutput model can replace existing dettronics controller based flame detection systems that generate a pulse output. No part of the hardware, software or documentation. How to merge pdfs and combine pdf files adobe acrobat dc. If the polymer separator is melted due to high temperature, an internal shortcircuit may occur in the individual cells and the battery may generate heat or smoke, rupture, or burst into flame. The rs485 modbus signal output is not part of the sil certification. It offers all benefits of failsafe ir measurement technology for applications in rough environments. Gas detection systems, air monitors, detectors teledyne. Highspeed flame detectors are used to detect quick burning flammable gas or material and are usually interlocked with suppression systems. It responds to the light emitted from flames during combustion. The simtronics multiflame dmtv6v combined uv and ir flame detector offers excellent flame detection whilst maintaining outstanding false alarm immunity. C7076d1027 honeywell, ultraviolet, solid state, self check flame detector.
Power the devices around your home including baby monitors, remote controls, roomba, mosquito magnets and more with a fresh battery. Rc systems stateoftheart sensmart 6100 ec gas detectors are are built with our proven st44 transmitters. This document is fd user manual2003issue 1 flame detector user manual general description the flame detector is designed for use where open flaming fires may be expected. The glt exports optical flame detector described in this document is the property of glt exports inc.
The fl3100h uvir flame detector is designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. Curious as to why multispectrum ir flame detectors were developed and rapidly adopted as the optimal choice, replacing uvir flame detection in oil and gas facilities. X5200 uvir flame detector by dettronics detector electronics corporation is part of carrier, a leading global provider of inno. Flame and gas detection are two options in operational hazards that require fast detection and explosive environments.
Ir flame detector ace control solution engineering. Uvir flame detector with pulse output x5200, x5200g, x5200m important be sure to read and understand the entire instruction manual before installing or operating the flame detection system. The model cxdm gas detection sensors can be easily and economically deployable in both permanent and temporary installations these low power sensor assemblies make use of electrochemical technology for a long list of toxic gases. Uvir flame detector x5200 description the evolution continues with the new x5200 uvir flame detector.
Improper response to simulated flame loss results in a. This flame detector series rapidly and accurately senses unwanted fires, issuing alarm outputs directly from the detector, providing reliable and secure protection of people, equipment and facilities. Precalibrated sensor, directly replaceable by user. Any deviation from the recommendations in this manual may impair system performance and compromise safety. Fl3100 series flame detectors the versatile fl3100 flame detector series is designed for a wide variety of flame detection applications.
The device offers a wide range of output options, as standard, and is suitable for use in sil 2 applications. The x5200 combines the technologies used in the x2200 and x9800 to provide unparalleled detection capabilities and. Long range flame detector capable of detecting a flame at a distance in excess of 100m. Ur600 ir provides the detector control unit, uvisor mfd, with a raw flame signal significant of the amplitude and frequency flicker of the infrared radiation detected in the primary combustion zone. Longrange flame detector activation at a range up to 20 ft 6 m. Each detector is equipped with a colour cctv camera. Easily combine multiple files into one pdf document.
The salwico gas detection system can be used on vessels such as cruise ships, lng carriers, car carriers, navy ships and many more. Salwico gas detection systems salwico produces various gas detection systems that can be used in the maritime market. The dmtv6v is designed to respond to unwanted hydrocarbon fires. Detector only covers the use of the standard analog 420 ma output. The mounting arrangement allows the uv and ir sensors to. The high performance, universal sensmart 6100 ec toxic gas detector supports our electrochemical sensors and is csa certified for class 1, division 1 locations. Eight channels of detection wide operating temperature range unique multiaxis reflective cone lensing system wide field of view solid state controlled focal adjustment. The flame detector is mainly used in largescale power plants, thermal power stations and chemical plants as well as for monitoring furnaces which are operated from oil gas biomass dust coal chemicals and other waste products. The model fl3112 flame detector processes these ir signals with a microcomputer and, depending on the. The flame detector is designed for use with dynamic selfcheck ultraviolet amplifiers r7476a and r7886 to provide a closedloop, selfchecking circuit which insures the integrity of both amplifier and flame detector. The ur600 ir is a self checked detector specifically designed to detect individual burner flames from atomized oil and pulverized coal fuels.
The detector discriminates between flames and other. View and download kenwood nx 5200 user manual online. Ge security nx491nt smoke detector home and electronic batteries from batteries plus bulbs. Scintillation detectors the disadvantage of gas filled counters is their low efficiency. Detector electronics corporation 2003 printed in usa 403 90115601 specification data uvir flame detector x5200 dettronics description the evolution continues with the new x5200 uvir flame detector.
Domestic lpg gas detector beagle plus with facility for driving 230v cutoff valves. Long range flame detector applications features detection in excess of 100m atex approved for zones 1,2 and 21, 22. The x5200 combines the technologies used in the x2200 and x9800 to provide unparalleled detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. Our dedication to safety, backed by more than 100 years of gas detection experience, has made us a global leader in flame and gas detection systems reliable, precision gas detectors for industrial applications. A tricolor led on the detector faceplate indicates normal condition and notifies personnel of fire alarm or fault conditions. The new range of uvir and triple ir flame detectors detect fuel and gas fires at long distances with the highest immunity to false alarms.
Any deviation from the recommendations in this manual may. Safetycertification of the ir700 includes the 420 ma output. Approved to fm 3260 2000, the x5200 meets the most. The zt500ex can detect the same fire at 65m in less than 5 seconds. Sensmart 6100 ec gas detector toxic gas detection rc. The corporate headquarters of dettronics is located in minneapolis, mn, usa, where flame, gas, mitigation products, and systems are designed, manufactured, and tested for installations around the world. Why the migration from uvir to 3ir flame detection in oil. The detector is equipped with automatic, manual and magnetic oi test capability. Instructions 958546 uvir flame detector x5200 detector electronics corporation 6901 west 110th street minneapolis, minnesota 55438 usa tel. The model fl3112 detects the infrared spectral regions of flame to produce a. The x3302 detects hardtosee hydrogen flames and other noncarbonbased materials without the false alarms associated with traditional technologies.
The 2020mi ir3 is also available as intrinsically safe approved. Ge security nx491nt smoke detector home and electronic. New smart test lamp for uv, uvir and ir flame detectors. Apollo intelligent base mounted uv dual ir flame detector 55000023apo. The x9800 meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. Its 100ft onaxis and 100ft offaxis detection range makes it an ideal solution for hydrogen surveillance by providing four times the coverage than conventional.
1446 216 754 262 37 555 623 840 444 306 311 734 417 631 1498 981 538 925 1315 735 225 1240 1226 1075 800 283 160 714 1382 1051 676 512 704 1410 1172